Care should be taken to prevent water ingress from the balcony area to the internal habitable space, structure or building envelope to which the balcony structure is attached.
Junctions with the main structure and threshold detailing must be considered during the design stage.
The following drainage approaches are suitable for warranty:
This article will provide a brief summary of each of the above drainage strategies along with some typical details. For more detailed guidance on balcony drainage strategies, please refer to the 'Roof Terraces and Balconies' section of our latest Technical Manual.
For projects being managed by our Major Projects team it is suggested that you contact you Major Projects Manager to discuss drainage strategies for projecting balconies on your development
With a positively drained balcony design, water is collected on a waterproof surface and directed to a piped outlet into the wider drainage network. A conspicuous over flow is used to warn of outlet/downpipe blockage and so avoids the risk of flooding to the balcony area.
This is a design approach which allows water to quickly pass through a pedestrian surface through to a soffit collection tray or impervious surface laid to falls. Where it is then momentarily collected and drained away from the weatherproof envelope of the building so that it does not cascade onto another balcony and discharges to a lower level where the water is appropriately managed.
For effective edge drainage, a linear gap is to be provided and must create at least a permanent 20mm wide opening at the leading edge. It should be continuous across the entirety of the width of the balconies leading edge. Chutes or pipes draining directly to an open area are not acceptable.
Any edge drained approaches should ensure as much as practicable that drainage should not be interrupted, for example by any supporting structure or similar. Edge drainage should also be evenly distributed and balcony projections for edge drainage should be restricted to 2500mm.
Where a free draining approach is used, water is not collected on a membrane or impervious surface but allowed to dissipate through a number of perforations in the balcony substrate, meaning that any hydraulic head of water is avoided. The pedestrian surface is designed to ensure that water is not collected and stored in any way. The pedestrian surface and the water collecting surface are the same.
The following must be considered where a free drained approach is proposed:
This article has outlined three strategies for draining rainwater from a projecting balcony. The latest version of our Technical Manual provides more detailed guidance on each of these strategies and this should be reviewed prior to the drainage strategy being drawn up by the designer.
Read more articles on InSite and sign up to receive our blog round-up.
Every care was taken to ensure the information in this article was correct at the time of publication (August 2024). Guidance provided does not replace the reader’s professional judgement and any construction project should comply with the relevant Building Regulations or applicable technical standards. For the most up to date Premier Guarantee technical guidance please refer to your Risk Management Surveyor and the latest version of the Premier Guarantee Technical Manual.